Comparison between two models of spo2 sensors and a system commercial embedded for blood oxygen level measurement

Authors

Keywords:

Oxímetro, SpO2, saturación, oxígeno, análisis, validación, funcionamiento

Abstract

In this article, an analysis of the operation and characterization of sensors for the measurement of the level of oxygen in the blood of users is carried out, as well as the characteristics of software and hardware that they may present are considered. The way in which the SpO2 sensors work, and the variables involved in the measurement of the oxygen levels presented are described. A visual and mathematical comparison of the measurements made by these devices and the margin of error that may occur between the measurements made by an embedded device for measuring SpO2 levels, a commercial watch with said integrated function and an Arduino sensor that It requires the development of programming and hardware to put it into operation.

Downloads

Download data is not yet available.

References

Alor-Hernandez, J. A., Alor-Hernández, G., Cruz-Ramos, N. A., Sánchez-Cervantes, J. L., & Rodríguez-Mazahua, L. (2022). Desarrollo de un módulo para la prevención de la hipertensión usando el paradigma IoT y aprendizaje automático. http://repositorios.orizaba.tecnm.mx:8080/xmlui/bitstream/handle/123456789/715/Desarrollo%20de%20un%20modulo%20para%20la%20prevencion%20de%20la%20hipertension%20usando%20el%20paradigma%20IoT.pdf?sequence=1

Bencomo, S., Villazana, S., & Salas, B. (2016). Design and construction of a pulse oximeter. Diseño y construcción de un oxímetro de pulso. Rev Ing UC, 23(2), 162-171. http://servicio.bc.uc.edu.ve/ingenieria/revista/v23n2/art06.pdf

Bolaños, D. (2018). Sensor de pulso cardiaco. Recuperado de http://www. bolanosdj. com. ar/MOVIL/ARDUINO2/TeoriaSensorPulsos. pdf.

Cornelio, O., Gulín González, J., & Santana Ching, I. (2021). Sistema de Laboratorios Remoto para las prácticas de control de la carrera de Ingeniería en Automática. Revista Cubana de Ciencias Informáticas, 15(2), 77-95.

Documentation, A. (2015). What is Arduino. Dostupné z: https://www. arduino. cc/reference/en.

Gallardo, J. R., Del Águila, R., & Parlanti, G. (2019). Testeo de oxímetro de pulso mediante optoelectrónica. https://rdu.unc.edu.ar/bitstream/handle/11086/23221/54.pdf?sequence=1

Mar Cornelio, O. (2019). Modelo para la toma de decisiones sobre el control de acceso a las prácticas de laboratorios de Ingeniería de Control II en un sistema de laboratorios remoto.

Mar, O., Gulín, J., Ivan Santana Ching, & Fonseca, B. B. (2020). Remote Laboratory System for Automatic Engineering. International Journal of Wireless and Ad Hoc Communication, 1(2), 55-63.

Mendoza, J. A. L. (2021). El oxímetro de pulso y el COVID-19. + Ciencia(25), 17-18. http://publicaciones.anahuac.mx/masciencia/article/download/561/515

Newcombe, R. G., & Merino Soto, C. (2006). Intervalos de confianza para las estimaciones de proporciones y las diferencias entre ellas. Interdisciplinaria, 23(2), 141-154. http://www.scielo.org.ar/scielo.php?pid=S1668-70272006000200001&script=sci_arttext&tlng=pt

Rana, V., Le Nguyen, T., Raghava, V., & Menon, P. G. (2021). Intelligent patient monitoring for proactive alerting of key personnel in intensive care: A single-center study. 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC),

Sánchez-Zurita, H. (2011). Outcomes from patients monitored with pulse oximetry and capnography during anesthesia. Revista Mexicana de Anestesiología, 34(S1), 21-22. https://www.medigraphic.com/pdfs/rma/cma-2011/cmas111d.pdf

Published

2023-01-27

How to Cite

Montalvo Torres, B. A. ., Fuenmayor Roca, A. R. ., Ñacato Estrella, D. R. ., & Zavala Ruiz, W. G. . (2023). Comparison between two models of spo2 sensors and a system commercial embedded for blood oxygen level measurement. Revista Científica Arbitrada Multidisciplinaria PENTACIENCIAS - ISSN 2806-5794., 5(1), 492–506. Retrieved from https://editorialalema.org/index.php/pentaciencias/article/view/466

Issue

Section

Artículos originales